KSA +966 57 281 2126 India +91 90288 12126 info@teczodus.com
← All insights

Going Digital in Pathology: What Labs Need First

AI & Innovation · · TecZodus Global

Radiology went digital two decades ago. Pathology is now on the same journey, but the glass slide is a harder object to replace than a film. A single scanned slide can be far larger than a typical imaging study, the diagnostic stakes are just as high, and the workflow touches the histology bench, the laboratory information system (LIS), the archive and the pathologist's desk all at once.

For laboratory heads and hospital CIOs, the question is rarely whether to go digital. It is what has to be in place first so that the investment delivers faster turnaround, easier second opinions and a path to AI, rather than an expensive scanner sitting in a corner.

What whole-slide imaging actually changes

Whole-slide imaging (WSI) scans an entire glass slide at high magnification and stores it as a multi-resolution image that the pathologist can pan and zoom like a digital map. Regulators have accepted WSI for routine diagnosis for several years: the US FDA permitted marketing of the first WSI system for primary diagnosis of surgical pathology slides in 2017.

The practical shift is that the slide becomes data. Cases can be distributed across sites, sent for subspecialty review without couriers, compared side by side with prior material and fed into image analysis. The flip side is that the laboratory now carries IT responsibilities it never had with a microscope: storage, networks, identity management, uptime and cybersecurity.

Digital pathology workflow from accession to sign-out
Digital pathology workflow from accession to sign-out

Infrastructure: scanners, storage and network

Scanners are the visible purchase, but they are rarely the bottleneck. Plan around three questions.

  • Throughput: how many slides per day must be scanned, and by when, so that digital sign-out is not slower than glass? Include rescans for focus or tissue-detection failures.
  • Storage: WSI files are large, and volumes grow quickly once routine histology is scanned. Decide early what is kept online, what moves to cheaper tiers and what retention period your regulations and clinical policy require. Model costs on your own slide volumes and measured file sizes, not brochure figures.
  • Network: images move from scanner to archive and from archive to viewing stations, often across sites. Test real viewing performance from remote locations before go-live; a pathologist waiting for tiles to load will quickly return to the microscope.

Viewing stations deserve attention too: suitable displays, reliable input devices and an ergonomic set-up for people who will now read every case on screen.

LIS integration and standards

Digital pathology succeeds or fails on integration. The slide barcode must carry the identity of the patient, specimen, block and stain from the grossing bench to the viewer, and the pathologist should launch cases from the LIS worklist rather than searching a separate system.

Standards make this sustainable. DICOM, already the backbone of radiology, defines how whole-slide images are stored, through the WSI work introduced in DICOM Supplement 145: each resolution level of the image pyramid is held as a tiled, multi-frame object. Using DICOM means slides can be managed in an enterprise archive alongside radiology, and the laboratory is not locked into one proprietary file format. For scanner workflow, DICOM's own WSI guidance points to HL7 v2 messaging profiled by IHE for digital pathology image acquisition, rather than the worklist services used in radiology.

When assessing any solution, ask for evidence of DICOM WSI export and import, HL7 integration with your LIS and the ability to migrate images out if you change platforms later.

Validation before clinical use

No laboratory should switch to digital sign-out without validating the system for its own intended use. The College of American Pathologists (CAP) guideline on validating WSI for diagnostic purposes, updated in 2021, is the most widely referenced framework. Its strong recommendations include:

  • A validation set of at least 60 cases for one application or use case, reflecting the specimen types and diagnoses seen in routine practice, with around 20 further cases suggested for additional applications such as immunohistochemistry.
  • A washout period of at least two weeks between a pathologist reading a case digitally and on glass.
  • Measuring intra-observer agreement between digital and glass diagnoses; if agreement is below 95%, the laboratory should investigate and resolve the cause. CAP stresses that this figure is not a simple pass or fail threshold.

Local regulators and accreditation bodies may add their own requirements, so build validation into the project plan from day one and document it thoroughly.

Where pathology AI fits

Pathology AI is advancing quickly: algorithms that flag suspicious regions, count mitoses, quantify biomarkers or prioritise worklists. None of it works without a reliable digital foundation. AI needs consistently scanned, well-labelled images, an integration route into the pathologist's viewer and a way to return results to the LIS and report.

Treat AI as phase two. Choose an architecture that can host or connect to multiple algorithms through open interfaces, insist on clear regulatory status for each intended use, and plan for local performance checks, since stain protocols and scanners differ between laboratories. The pathologist remains responsible for the diagnosis; AI should reduce effort and variability, not add another screen to check.

Digital pathology readiness checklist
Digital pathology readiness checklist

Readiness checklist

Before signing a purchase order, a laboratory should be able to tick most of the following.

  • A defined first use case (for example, one subspecialty, frozen sections or external consultations) rather than scanning everything on day one.
  • Measured daily slide volumes and turnaround targets that drive scanner sizing.
  • Histology quality improved for scanning: consistent section thickness, clean slides, reliable labels and barcodes.
  • A storage and retention plan with realistic multi-year cost modelling.
  • Network capacity tested between scanners, archive and every reading location.
  • LIS integration scope agreed, including barcode formats and case launch from the worklist.
  • A commitment to DICOM and open interfaces to avoid future lock-in.
  • A validation protocol aligned to recognised guidance and local regulation.
  • Training, change management and pathologist champions identified.
  • Cybersecurity, access control and downtime procedures, including a fallback to glass.

Conclusion

Digital pathology is one of the most significant changes in laboratory medicine in a generation, and the benefits are real: distributed reading, faster consultations, better teaching and a foundation for AI. But the order matters. Laboratories that get specimen quality, integration, standards and validation right first find that scanners and algorithms slot in naturally. Those that start with the hardware often spend the next two years fixing the foundations.

Planning a digital pathology project? Talk to our team at info@teczodus.com.

Sources

Working on a project like this?TecZodus Global helps hospitals, imaging centres and healthcare software vendors across Saudi Arabia, the GCC, India, Europe and North America.
Talk to an expert

More insights